Application Note

AcidiFluor™ Series

Code no. Product Examples of Application Size
GC301 AcidiFluor™ ORANGE Used to label lysosomes. 10 μg × 20
GC302 AcidiFluor™ ORANGE-NHS Used to label antibodies or proteins. 1 mg
GC303 AcidiFluor™ ORANGE-NHS Subdivided packaging. Used to label antibodies or proteins. 5 times
GC305 AcidiFluor™ ORANGE-Zymosan A Used to study phagocytosis 1 mg
GC305 AcidiFluor™ ORANGE-Zymosan A Used to detect phagocytosis in a flow cytometer 1 mg
GC306 AcidiFluor™ ORANGE-Dextran 10k Used to study phagocytosis 1 mg
GC307 AcidiFluor™ ORANGE-Beads 500 Nano-sized silica particles labeled with AcidiFluor™ ORANGE, used to study cellular uptake such as endocytosis. 500 nm/250 μg
GC308 AcidiFluor™ ORANGE-wBeads 500 FITC containing beads used as a pH sensor for easy tracking. 500 nm/250 μg

CalFluor™ Seires

Code no. Product Examples of Application Size
GC401
GC402
CaSiR-1 Near-Infrared Ca2+ probe  (Under construction)
Near-Infrared Ca2+ probe Subdivided packaging. (Under construction)
1mg
50μg×20
GC403 CaSiR-1 AM Near-Infrared Ca2+ probe For live-cell imaging (Under construction) 50μg×20
GC501
GC502
CaTM-2 Red-fluorescent Ca2+ probe for visualizing fluctuation of Ca2+ in cytoplasm.
Subdivided packging for trial.
500μg
50μg×10
GC503
GC504
CaTM-2 AM Easy type to introduce in cell. For live-cell imaging.
Subdivided packging for trial. For live-cell imaging.
500μg
50μg×10

GlycoFluor™ Series

Code no. Product Examples of Application Size
GC601 GlycoYELLOW™-βGal Imaging radiation-induced senescence by GlycoYELLOW™-βGal Screening of β-galactosidase activity 50μg×10
SK4001-01 TokyoGREEN®–βGal Imaging of galctosidase in living cells. 1mg

SuperFluor™ Series

Code no. Product Examples of Application Size
A202-01 HMSiR labeled Goat anti-mouse IgG (whole) Superresolution imaging using HMSiR™-labeled secondary antibodies 100 μg
A203-01 HMSiR labeled Goat anti-rat IgG (whole) 3D-STORM imaging of microtubules using NIKON N-STORM super-resolution microscope 100 μg
A204-01 HMSiR labeled Goat anti-rabbit IgG (whole) 3D-STORM imaging of microtubules using NIKON N-STORM super-resolution microscope 100 μg

HypoFluor™ Series

Code no. Product Examples of Application Size
A101-01 MAR Hypoxia detection in spheroids 25μg×5

ROSFluor™ Series

Code no. Product Examples of Application Size
GC3004-01 OxiORANGE Orange color Fluorescent Probe for detecting hROS 100nmol ×5
GC3007-01 HYDROP Live-cell imaging of intracellular H₂O₂. 30nmolx3
GC3008-01 HYDROP-EX Reactivity of HYDROP-EX with reactive oxygen species. 30nmolx3
SK3001-01 Hydroxyphenyl Fluorescein (HPF) Measurement of reactive oxgen species 1mg
SK3002-01 Aminophenyl Fluorescein (APF) Measurement of reactive oxgen species 1mg

FRETFluor™ Series

Code no. Product Examples of Application Size
A401-1 QuicGSH3.0
A402-1 SSip-1 DA Reactivity of SSip-1 DA with sulfane sulfur.
Effect of SSip-1 DA for cells

POLARIC™ Series

Code no. Product Examples of Application Size
GC101 POLARIC™-500c6F Cell Imaging with POLARIC™-500c6F 1μg×10
GC102 POLARIC™-500BCS Bacterial Imaging with POLARIC™-500BCS 5μg×10
- POLARIC™ for labeling nucleic acid and protein -

Labeling Services

Code no. Product Examples of Application Size
- Phagocytosis of POLARIC™ conjugated β-amyloid by Microglia -

Publications

Code no. Product Examples of Application Size
- Publication (1) – Application to membrane potential‐sensitivity dyes -

Start typing and press Enter to search

Shopping Cart

No products in the cart.